Plan compressive strength test ages per ACI 318 / ASTM C39 โ Generate cylinder break schedule with maturity tracking
๐ Break Schedule
| Test Age |
Date |
Cylinders |
Expected Strength |
Acceptance Criteria |
Status |
๐ Strength Development Curve
๐
Configure Schedule
Enter project details and test ages in the sidebar, then click Generate Schedule.
๐ก๏ธ Maturity Method (ASTM C1074)
๐ก๏ธ Nurse-Saul Method
M = ฮฃ(T - Tโ)ฮt. Simple time-temperature summation. Tโ = -10ยฐC for Type I cement. Best for normal concrete.
โ๏ธ Arrhenius Method
te = ฮฃexp[E/R(1/Tโ - 1/T)]ฮt. More accurate for varying temperatures. E = 33,500 J/mol for Type I.
๐ Strength-Maturity Curve
Log(S) = a + bยทlog(M). Calibrate with 3+ cylinder breaks at different ages. Track in-place strength real-time.
๐๏ธ Field Application
Embed iButton/loggers in critical pours. Read maturity โ estimate strength โ make formwork removal, post-tensioning, loading decisions.
๐ Break Schedule Report
๐
No Schedule Generated
Generate a schedule in the Builder tab first.
โ Back to Concrete Testing