Back to Concrete Tests

Fresh Concrete Temperature

Temperature of freshly mixed concrete per ASTM C1064 / EN 12350-4

Test Level
Placement & curing control
🌡️
STEP 1 / 1
Fresh Concrete Temperature
Verify concrete is within placement temperature limits
🌡️
Enter Temperature Readings
Enter concrete, ambient, and material temperatures to evaluate compliance.
📝 Standards
  • ASTM C1064: Standard Test Method for Temperature of Freshly Mixed Hydraulic-Cement Concrete
  • EN 12350-4: Testing fresh concrete - Temperature
  • Acceptable range: 10°C to 30°C (typical specification)
  • Thermometer stem must be immersed at least 50 mm into concrete
  • High temperature (>30°C) accelerates setting and reduces ultimate strength
🤖 SmartLab Stages (مراحل سمارت لاب)

Connect your SmartLab device and follow the guided stages to run this test automatically.

💡 The SmartLab content below is managed through the Test Zones system (available to administrators).