Compaction Curve

Standard & Modified Proctor Analysis โ€” Plot dry density vs moisture content, determine MDD & OMC per AASHTO T 99/T 180 / ASTM D698/D1557

๐Ÿ“Š
Proctor Compaction Analysis
Enter lab compaction data points. Auto-fit curve, calculate Maximum Dry Density (MDD) and Optimum Moisture Content (OMC). Compare Standard vs Modified.
๐Ÿ“Š
Enter 3-5 Data Points
Input moisture content and dry density from lab. Click Analyze Standard.
๐Ÿ“Š
Enter Modified Data

โš–๏ธ Standard vs Modified Comparison

๐Ÿ“
Std MDD
-- pcf
๐Ÿ’ง
Std OMC
-- %
๐Ÿ“
Mod MDD
-- pcf
๐Ÿ’ง
Mod OMC
-- %
๐Ÿ“ˆ Standard vs Modified Curves
๐Ÿ“Š Energy Comparison
Standard (T 99/D698): 5.5 lb hammer, 12" drop, 3 layers, 25 blows/layer = 12,375 ft-lbf/ftยณ
Modified (T 180/D1557): 10 lb hammer, 18" drop, 5 layers, 25 blows/layer = 56,250 ft-lbf/ftยณ
Ratio: Modified energy โ‰ˆ 4.5 ร— Standard
๐Ÿ“ˆ Typical Differences
MDD (Modified) โ‰ˆ MDD (Standard) + 10-15 pcf
OMC (Modified) โ‰ˆ OMC (Standard) - 2-3%
Higher energy โ†’ denser packing at lower moisture
๐Ÿ›ฃ๏ธ Application
Standard: Light traffic, embankments, trench backfill
Modified: Heavy traffic, runways, highways, foundations
Use modified when compaction equipment delivers high energy